
Closed
Posted
Paid on delivery
An HSIC-Class metal fence with an integrated gate is scheduled for installation on a rural site. I will supply the current drawings, material specs, and every standard that must be observed; your task is to verify the whole foundation concept and document the structural adequacy. Scope • Perform a full wind-load analysis on the fence and gate, using the design wind speed stated in the material I provide, then convert pressures into line and point loads. • Check overturning, sliding, and bearing stability for each post footing and for the gate support structure. • Size or confirm concrete footing dimensions, reinforcement, and embedment details. • Summarise all safety factors, governing load cases, and reference clauses from the supplied standards. Deliverables 1. Calculation report (PDF) with clear inputs, step-by-step formulas, and final utilisation ratios. 2. Editable spreadsheet or calculation sheet (Excel / MathCAD) so values can be updated later. 3. Mark-ups on the original drawing set showing any footing or reinforcement changes. Acceptance criteria • Load combinations match the provided code. • Utilisation ratios ≤ 1.0 for all checks. • Footing geometry fits the site constraints noted in the drawings. Please indicate the software you intend to use (e.g., STAAD, Robot, SAP2000, hand-calc spreadsheet) and your typical turnaround time once you have received the design package. The design must comply with SBC 301/304, BS 8110-1997, BS 1722 Part 10, and ASTM (A-53/C39) standards, utilizing criteria of 54 m/s wind velocity, 150 kN/m² soil bearing, C35 concrete grade, and a 1.5 safety factor against overturning and slip Complete wind load calculations and load combinations shall be provided with reference to the adopted code. Complete foundation stability calculations shall be submitted, including overturning, sliding, bearing, and uplift checks. Foundation reinforcement details and material specifications shall be provided. Typical sections/details used in the calculations shall be included in the calculation report with reference to the relevant drawings. The structural design must adopts a minimum safety factor of 1.5 for overturning and slip (ULS) Please include detail structural strength calculation for the adopted post. Show the utilization of the post the soil bearing capacity of SLS and ULS increased the allowable soil bearing pressure which is taken as 150Kpa. The design wind speed for the gate is considered as 54 m/s and for the foundation base design wind speed is 44 m/s which mis aligns togather, and does not meet the project design guidelines as per EPC contract. The design wind speed is to be 56.5m/s. epc to revise the calculations accordingly
Project ID: 40577086
14 proposals
Remote project
Active 1 min ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
14 freelancers are bidding on average $173 USD for this job

Hello, I am a Strucutral engineer with 10+ years experience, I am expert in Structural analysis and designs of different structures so i can do the required design drawings and calculations in the required time. I have finished similar projects before and finished 600+ projects. Please check my portfolio and reviews. Thanks.
$175 USD in 3 days
8.4
8.4

Hi, I am a professional structural engineer with over 09+ years of experience in structural analysis and design. I have worked on similar projects and have relevant experience. I can provide you with the requisite qualitative work. Please feel free to contact me to discuss further. Thanks & regards, Ghullam Hussain P.E. (Structures)
$200 USD in 5 days
7.4
7.4

Hi there, I have more than 15 years of experience in engineering and structural design, including structural assessments, steel structures, and foundation design for wind-loaded installations. I can verify your HSIC-Class metal fence and gate foundation design, perform the required wind load and stability analyses, and prepare a complete calculation package in compliance with SBC 301/304, BS 8110-1997, BS 1722 Part 10, ASTM standards, and your EPC requirements. Please check my portfolio and client reviews. Deliverables • Complete wind load and load combination calculations. • Post strength and utilization calculations. • Foundation stability checks (overturning, sliding, bearing, and uplift). • Reinforcement details with marked-up drawings. • Editable Excel calculation sheets and PDF report. • One revision based on your feedback. I use SAP2000, STAAD Pro, and Excel spreadsheets for structural analysis and can revise the design to the required 56.5 m/s design wind speed. I can start immediately. Regards
$175 USD in 3 days
6.5
6.5

With my experience in civil and structural engineering, I am confident I can deliver beyond your expectations on this project. Having worked on designs for similar metal structures before, I'm well-versed with wind-load analysis and calculating foundation stability. My knowledge of the SBC 301/304, BS 8110-1997, BS 1722 Part 10 standards aligns perfectly with your project requirements. Proficiency in software such as STAAD, Robot, SAP2000, and hand-calc spreadsheets are the tools I plan to utilize for your project. Considering the complexity of the task at hand and to ensure high safety standards, I'll employ a thorough approach towards every step of this assignment. My typical turnaround time averages efficiency without compromising on quality. More than just delivering on your specified requirements, my commitment is also to deliver a comprehensive calculation report that you can have confidence in. This report will not only detail inputs but will also provide step-by-step formulas and final utilization ratios. And because you value adaptability, I'll ensure to include an editable spreadsheet or calculation sheet for future usage. Choosing me means partnering with a diligent professional who has successfully completed similar challenging projects ensuring that design standards are not just met but exceeded.
$120 USD in 2 days
5.9
5.9

Having profiled diverse engineering projects and acquired advanced skills in AutoCAD, SolidWorks, Revit, SketchUp, Tekla, and even undertaking structural calculations with SAP2000, I have extensive knowledge about the critical role proper foundations play in ensuring structural integrity. Given this understanding, the task of verifying the whole foundation concept for your HSIC-Class metal fence project is well within my capabilities. Complementing my technicality is my knack for visual aesthetics and clarity which would manifest in summative deliverables as you've specified: a calculation report with clear inputs & step-by-step formulas, an editable spreadsheet/calculation sheet so values can be updated later and mark-ups on your original drawing set indicating any footing or reinforcement changes made.
$66 USD in 1 day
5.3
5.3

Hello " Lets Gets Started, You are looking for Fence Foundation & Wind Load Calculations I know you have several tempting proposals here, but I guarantee you to be impressed by my work. I have various skills in Structural Engineering and Civil Engineering. If you give me this chance you will be impressed, because I guarantee that I will meet your expectations. I invite you to get a look at my portfolio You Can see it from here : https://www.freelancer.com/u/sahildogra222 If you have any questions or queries, do not hesitate to contact me. I hope to start working with you. With regards! Sahil
$30 USD in 1 day
3.8
3.8

I would appreciate the opportunity to work on your fence foundation and wind load verification project. As a structural engineer with experience in steel structures and foundation design, I can deliver a complete calculation package fully compliant with SBC 301/304, BS 8110:1997, BS 1722 Part 10, and the applicable ASTM standards. I will perform comprehensive wind load calculations using the revised EPC design wind speed of 56.5 m/s, develop all required load combinations, and verify post strength, footing stability (overturning, sliding, uplift, and bearing), reinforcement, embedment depth, and utilization ratios. I will also review the inconsistency in the previously adopted wind speeds (54/44 m/s) and revise the design accordingly. Software: Excel calculation sheets with detailed hand calculations, STAAD Pro (if required for verification), and AutoCAD/PDF markups for drawing revisions. Deliverables: Detailed calculation report (PDF) with code references and step-by-step calculations. Editable Excel calculation workbook. Marked-up drawings showing any required footing or reinforcement modifications. Summary of governing load cases, safety factors, and utilization ratios.
$200 USD in 7 days
2.6
2.6

With my extensive background in Physics and Mathematics, especially in the realm of Classical and Quantum mechanics, Heat and Thermodynamics, Electrodynamics, and more, I bring the perfect set of skills to this project. As a researcher for sensors and nanogenerators, I'm accustomed to performing precise calculations with complex data - exactly what you need for your wind-load analysis and foundation stability checks. My proficiency in utilizing software such as STAAD, Robot, SAP2000, and MS Excel/MathCAD will ensure reliable calculations while the use of CAD tools like AutoCAD will enable me to accurately mark-up the original drawings as necessary. Moreover, my profound grasp of various international standards like SBC 301/304, BS 8110-1997, BS 1722 Part 10, and ASTM (A-53/C39) promises an in-depth comprehension of the codes involved. Additionally, I am well accustomed to working with a minimum safety factor requirement of 1.5 for overturning and slip (ULS) – exactly what you're looking for. For the deliverables, I'll provide a thorough calculation report with clear inputs, formulas, final utilization ratios; an editable spreadsheet or calculation sheet with great flexibility; as well as marked-up drawings showing all changes made regarding footings and reinforcements.
$250 USD in 7 days
0.8
0.8

Hi, I can verify the complete fence and gate foundation design, including wind loading, post strength, footing stability, reinforcement, and code-compliance checks. The best solution is to first review the drawings, fence/gate geometry, post sections, material grades, soil data, and supplied standards. I’ll then calculate wind pressures using the required 56.5 m/s design speed, convert them into line and point loads, and check all governing ULS/SLS combinations. I’m comfortable with structural hand calculations, Excel/MathCAD, STAAD/Robot/SAP2000 review, wind-load analysis, steel-post design, concrete footing design, reinforcement detailing, and foundation stability checks. Deliverables will include: * Wind-load and load-combination calculations * Overturning, sliding, uplift, and bearing checks * Post strength and utilization calculations * Footing sizing and reinforcement details * Safety-factor summary * Code-clause references * Editable Excel/MathCAD sheet * PDF calculation report * Drawing mark-ups and typical details I’ll use a transparent calculation workbook supported by structural analysis software where needed, and deliver within 4–6 days after receiving the full design package. Best regards Ankit
$50 USD in 1 day
0.0
0.0

Riyadh, Saudi Arabia
Payment method verified
Member since Nov 3, 2021
$30-250 USD
$30-250 USD
$30-250 USD
$30-250 USD
$30-250 USD
₹600-830 INR
€750-1500 EUR
$250-750 USD
$1500-3000 USD
$750-1500 USD
$250-750 USD
$750-1500 USD
$250-750 USD
$15-25 USD / hour
$15-25 USD / hour
₹12500-37500 INR
$3000-5000 CAD
$250-750 USD
₹12500-37500 INR
£250-750 GBP
$250-750 USD
$250-750 USD
₹1500-12500 INR
₹600-1500 INR
$250-1000 USD