I’m moving forward with a new ISO 14644-1 Class 8 cleanroom dedicated to research and development work. Within the suite we will be compounding medications, running sterility tests and carrying out the final packaging / labeling steps, so the design must support smooth material flows, well-defined pressure cascades and easy compliance audits. You will start from my basic hand-sketches and translate them into a fully engineered package. That means refining the layout, sizing the HVAC system, specifying HEPA filtration, air changes and differential pressures, and locating pass-throughs, sinks, and gowning areas so that each activity can proceed without cross-contamination. If Revit or AutoCAD is your normal toolbox, perfect—models and drawings need to be export-ready for my facility contractor. Deliverables • Scaled floor plan and reflected ceiling plan showing clean/dirty zones and pressure regime • HVAC and mechanical schematics with ACH calculations, AHU selection and filter schedule • Bill of materials and data sheets for all critical components • Written design brief tying the solution back to ISO 14644-1 Class 8 requirements and relevant GMP guidance • One revision round after our internal safety review Acceptance criteria: the documents must demonstrate ≥20 air changes per hour, <3.5 m/s air velocity at diffusers, and clearly mark every room’s target particle count and pressure differential. If you have recent cleanroom design work in pharma or biotech R&D, I’d like to see a sample when we chat. Looking forward to getting this concept onto paper—and then into reality—together.
Project ID: 40507254
12 proposals
Remote project
Active 6 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
12 freelancers are bidding on average $322 USD for this job

With a project as intricate and vital as designing an ISO Class 8 cleanroom for your pharmaceutical company, I, Mannu, believe that my vast skill set and experience in Engineering and CAD Design perfectly align with your needs. I have proven myself capable of delivering high-quality technical drawings on AutoCAD, SolidWorks, and Revit, ensuring your project's specifications are met down to the last detail.
$66 USD in 1 day
6.9
6.9

My name is Kirandeep Kaur, and I specialize in bringing visions to life with creativity and precision. As a skilled Graphic Designer, Branding Specialist, and expert in 2D & 3D Modeling, your ISO Class 8 Cleanroom Design project is right up my alley. I have comprehensive experience in architectural visualization as well as drafting scaled floor plans, perfect for translating your hand-sketches into the detailed, engineered designs you need. Not only do I offer a complete engineering-related service package that aligns well with your deliverables list, but my understanding of pressure cascades, HEPA filtration systems and my attention to detail will guarantee designs that minimize cross-contamination risk. I look forward to showcasing this expertise in my past cleanroom designs when we chat so we can take your R&D operations to the next level together. Let's get started!
$60 USD in 1 day
6.6
6.6

Dear Sir, I would be happy to chat with you about adjusting the project scope, cost and timeframe. Please contact me to get started. Thanks. Introduction: I am an experienced Mechanical Design Engineers with 15+ years of experience in HVAC design. I successfully completed the design and installation of HVAC, Plumbing, Fire alarm, firefighting, Water Supply, Drainage, and Sewerage systems for various Residential and Commercial Projects as per standards and specifications. I have all the technical skills, experience, and practical project management skills to complete your task professionally and quickly. Well-versed in VRF system Design, Chillers, Cooling Towers, Pumps, VRF, Fire Sprinkler Systems, Fire Hose Reel systems, Fire Hydrant Systems, Septic tanks, Heat exchangers, Sump Pumps, Fire Alarm systems addressable or Conventional Systems. Skills: Revit MEP, Pro Engineer Wildfire, Solid works, Elite Fire (Hydraulic calculations), AutoCAD, Canute, MS Office, HAP 4.5 (Hourly-Analysis-Program), McQuay (Duct-size), McQuay (Pipe-size), Carrier psychometric chart.
$250 USD in 4 days
6.4
6.4

As a seasoned architect with a solid background in cleanroom design and ISO Class 8 requirements, I'm confident that I can deliver the tailored solution you need. My proficiency in AutoCAD, Revit, and other design software is complemented by my comprehensive understanding of HVAC, mechanical systems, and air quality management to ensure we meet and exceed your specifications.
$35 USD in 1 day
6.1
6.1

With my extensive background in design and engineering, especially with tools like AutoCAD and Revit, I reckon I can add substantial value to your cleanroom project. While my experience may not be directly in pharma or biotech R&D, I believe the skills I've honed as a 3D artist and designer can be effortlessly transferred to ensure your cleanroom meets ISO 14644-1 Class 8 requirements efficiently.
$45 USD in 1 day
4.3
4.3

Hello, I am interested in your ISO 14644-1 Class 8 cleanroom project and can help convert your hand sketches into a coordinated design package suitable for contractor pricing and facility development. Starting from your layout concepts, I will refine room arrangements, personnel and material flow, gowning areas, pass-through locations, and pressure cascades to support contamination control and efficient operations. Special attention will be given to the compounding, sterility testing, packaging, and labeling areas to reduce cross-contamination risks and simplify compliance reviews. The HVAC package will include ACH calculations, HEPA filtration strategy, AHU selection, airflow distribution, diffuser placement, and differential pressure requirements. All rooms will be clearly identified with their design criteria and environmental targets. Deliverables will include floor plans, reflected ceiling plans, HVAC schematics, equipment schedules, bill of materials, filter schedules, and a written design summary aligned with ISO 14644-1 Class 8 objectives and GMP considerations. One revision round will also be included following your internal review. I am available to start immediately and would be happy to review your sketches, workflow requirements, and project timeline.
$30 USD in 2 days
1.5
1.5

I would like to offer my services for your ISO Class 8 Cleanroom Design project. I am committed to delivering accurate, high-quality, and standards-compliant design work with full attention to detail and functionality. With experience in mechanical and architectural CAD design, I can develop cleanroom layouts that consider proper airflow zoning, contamination control principles, equipment placement, and efficient space utilization while aligning with ISO Class 8 requirements. I ensure clear communication throughout the project, timely delivery, and a result that meets both technical and practical expectations. Software & Tools Expertise: AutoCAD, SolidWorks, Autodesk Revit, Fusion 360, Blender, 3D Visualization, SketchUp, V-Ray, Adobe Photoshop, and other advanced CAD/3D design tools. I would appreciate the opportunity to work on your project and deliver a solution that meets your requirements effectively.
$1,000 USD in 7 days
0.6
0.6

Dear Sir or Madam, I've 25+ years of experience in pharma and biopharma industry. I was a core member in design of a new huge project done in cooperation with German and US based engineering and consultancy companies and later I designed about 4 facilities in compliance with EU & WHO GMP and willing to help you reach your GMP and EHS compliance in an efficient and lean way. Initial inputs from your side: 1- URS for area indicating purpose, list of products and materials and their toxicological data to define the required containment strategy, capacity needed, types of dosage forms .... etc. Note: I can help you developing a simple URS. Just send required inputs. 2- Avaiable space. 3- Available budget. 4- Your plan to procure nationally or internationally. 5- Target markets. 6- Regulatory authorities to comply with either for GMP, EHS or other applicable regulations. 7- Facility geographical location. Deliverables from my side: 1- Conceptual design with +/- 25% budget estimate. 2- Autocade layouts for classes, differential pressure, material flow, personnel flow, waste flow, emergency exit. 3- Containment strategy. 4- HVAC basic design with number of airchanges, types of filters and AHU design and sizing. You can add or remove any of deliverables and final bid will be based on requested activities. My slogan is providing international level of work at an affordable cost for SMEs. Warm regards, Morcos Loka, MBA, CMQ/OE, CQA, CPGP, CPIP
$2,000 USD in 45 days
0.0
0.0

Ca Mau, Vietnam
Member since Jan 30, 2023
$5000-10000 USD
$5000-10000 USD
₹600-1500 INR
$250-750 USD
$30-250 USD
$30-250 USD
$250-750 USD
$250-750 USD
₹1500-12500 INR
$750-1500 USD
$250-750 CAD
₹1500-12500 INR
₹600-1500 INR
$250-750 USD
$3000-5000 USD
£250-750 GBP
$15-25 USD / hour
$250-750 USD
$8-15 USD / hour
min ₹2500 INR / hour